Ozone Equipment & Systems
RUNHAO / OZONE TECHNOLOGYRH-D-F/YSPECIFICATION REFERENCE

RH-D-F/Y / RUNHAO

Large Oxygen-Fed Ozone Generator

A large ozone-generator range using oxygen feed gas. The listed output sizes span 0.5–30 kg/h under conditions to be agreed.

  • Oxygen-fed ozone generation
  • Larger output sizes
  • Cooling and dosing integration

The brochure supplies specifications without a dedicated photograph for this entry.

01 / APPLICATION

What this equipment does

Projects needing larger ozone output, integrated with the specified oxygen supply, cooling, monitoring and dosing system.

A large ozone-generator range using oxygen feed gas. The listed output sizes span 0.5–30 kg/h under conditions to be agreed.

02 / TECHNICAL DATA

Reference specifications

Source: company brochure, PDF page 28 left upper. Reviewed 5 November 2026.

On smaller screens, scroll the table sideways.

RH-D-F/Y brochure configurations
ModelOzone output (kg/h)Gas flow (Nm³/h)Overall dimensions (mm)
RH-D-F/Y5000.54–51200 × 600 × 1600
RH-D-F/Y100017–102000 × 1000 × 1800
RH-D-F/Y2000214–202000 × 1000 × 1800
RH-D-F/Y3000320–302300 × 1200 × 1600
RH-D-F/Y5000534–502300 × 1400 × 1600
RH-D-F/Y8000854–802300 × 1400 × 1600
RH-D-F/Y100001070–1002800 × 1500 × 1600
RH-D-F/Y1500015100–1503000 × 1500 × 1600
RH-D-F/Y2000020134–2003000 × 1500 × 1600
RH-D-F/Y3000030200–3003500 × 1500 × 1800

03 / PROJECT INPUTS

Define the application before choosing a size

Material or workpiece

Composition, form, bulk density or dimensions; moisture, viscosity and any special media.

Process and capacity

Required kg/batch or kg/h, acceptable temperature, processing time and quality endpoint.

Installation and validation

Available utilities, loading access, cleaning, controls and the agreed acceptance method.

Use the equipment selection guide

Questions about this equipment

What is the Large Oxygen-Fed Ozone Generator used for?

Projects needing larger ozone output, integrated with the specified oxygen supply, cooling, monitoring and dosing system.

Which specifications are available for the RH-D-F/Y range?

The table on this page lists the brochure configurations and their units. The source is the company brochure, PDF page 28 left upper. Confirm the current model, utilities and acceptance conditions before ordering.

What should I send with an equipment enquiry?

Send the material or workpiece details, required kg/batch or kg/h, temperature limits, process target, available utilities and installation space. Trial results and the agreed technical proposal define the supplied configuration.

Back to this equipment family

LET’S BUILD SOMETHING BETTER

Equipment starts with your process.

Share your material, required output and process conditions to discuss a suitable configuration.

Talk to Runhao